UHPC Ground Panels
Seamless UHPC wear-resistant flooring dedicated to heavy-load scenarios, with excellent impermeability, wear resistance and long service life. Suitable for industrial plants, commercial centers and other floor projects needing high durability and seamless neatness.
Physical Properties
Mix Design & Application
Water-Cement Ratio
Balance of high strength and wear resistance
Working Time
Minutes at 20℃ (meeting large-area paving)
Common Thickness
40-50mm for industrial heavy-load areas, 30-35mm for commercial areas
Test Standards

National Standard
GB/T 50081-2019、GB/T 16725-2021、GB/T 5464-2010、GB/T 50476-2019

International Standard
ASTM C109-23、ASTM C78-22、ISO 9284:2016、ASTM C1609-19
Primary Applications
Industrial Plant Floors
Heavy-load equipment workshops (e.g., automobile manufacturing, mechanical processing), forklift rolling resistance
Underground Garage Floors
Entrances, exits and driving lanes, wear and oil resistance, easy to clean
Logistics & Warehouse Floors
High-rack warehouses and logistics sorting areas, impact resistance and high flatness
Commercial Public Spaces
Shopping malls and airport terminals, slip resistance, low noise and aesthetics

Performance Benefits
Heavy Load Capacity
Compressive strength 180-220 MPa, meets heavy industrial equipment loads
Seamless Integration
No joint design, eliminates dirt accumulation, easy to clean and maintain
Installation Process
Substrate Preparation
Concrete base course needs grinding to rough surface, floating dust removed, interface agent applied
Mixing Preparation
Forced double-shaft mixer, mixing time 4-5 minutes, ensuring homogeneity
Mechanical Paving
Laser leveler for paving, thickness control ±2mm, surface troweling 2-3 times
Curing & Sealing
Apply sealant after 7 days curing to enhance stain resistance and glossiness
Equipment & Tools
Construction Equipmen
- Forced double-shaft mixer
- Laser leveler
- Concrete polishing machine
- Vacuum cleaner
Safety Equipment
- PPE (safety helmet, non-slip shoes)
- Dust mask (KN95 grade)
- Goggles
- Earplugs
Substrate Compatibility
Compatible Substrates
- Concrete C25 and above
- Epoxy floor (needs grinding)
- Steel plate (needs rust removal)
Incompatible Substrates
- Sanding floor
- Asphalt base
- Wooden floor
Additive Compatibility
Steel fibers
dosage 1.0%-2.0%, high-strength metal fibers that significantly improve UHPC tensile, flexural and impact resistance
RecommendedPolycarboxylate superplasticizer
0.8%-1.2%, a high-performance water reducer that significantly improves UHPC mixture fluidity and reduces water-binder ratio while maintaining strength
CompatibleCalcium chloride prohibited
common early strength agent but causes steel corrosion and seriously affects UHPC long-term durability
Consult Technical TeamEnvironmental Conditions
Optimal Conditions
Special Considerations
- Base course moisture content ≤4%
- Construction prohibited in rainy days and cooling measures required at high temperature